E-ITN 30.6
E-ITN 30.6
Heating cost allocator
- Modern design
- Data encryption with AES method
- Compliance with standards EN 13757-4:2005 and EN 834:1999
- Big and readable 8-position display with many intuitive symbols and units for the displayed values
Application
Features
Technical data
Downloads
Heating cost allocator equipped with a wireless data transmission system, characterised by the perfect use of operational potential contained in microprocessor technology, modern design and the data encryption with AES method.
Heating costs allocator E-ITN 30.6 has been designed for settlements carried out monthly and yearly as well. E-ITN 30.6 calculates the cost of heating in space. Recommended scope of application includes horizontal or vertical heating systems with one or two pipes with an average minimum design temperature of heat-transfer medium no less than 35°C and maximum one no more than 90°C.
- The wireless data transmission system is implemented by: an IR port - a direct readout with a reader; and a radio interface - a remote readout implemented outside the premises with allocators installed.
- The allocator is equipped with an ergonomically located LCD display that enables the user to easily read out the values of current heat consumption. In addition, these data are recorded in the internal memory, so it is possible to make a full analysis of heat consumption and the conditions in which the heat allocator worked in a whole heating season.
- Heat allocator E-ITN 30.6 provides a precise measurement of heater temperature. The installation and configuration of any additional devices is not required. HCA calculation is based on the software that allows a fair settlement of the cost to heat used for the specific apartment.
- Any attempt of unauthorised manipulation (broken e-locks), an attempt to remove heater with attached allocator or the use thermal barriers before heater (furniture, curtains, etc.), is recorded with the exact date of its occurrence. The information about the manipulation is transmitted during the forthcoming radio readout.
Display | Five-digit liquid crystal display + 2 special characters. Data Archive: archiving measurements including the time of event occurrence. |
General billing factor | Individual scale |
Function monitoring | Automatic, activated and controlled from the outside |
Power supply | 3 V lithium battery |
Operation life of the device | 10 years + 1 year of reserve |
E-lock | Yes |
Infra contact | Yes |
Radio module | Yes |
Dimensions | 100 x 37 x 33 mm |
Material | ABS + PC / Al – F22 |
Safety class | IP42 |
Scope of use | tmax ≤ 90°C, tmin ≥ 35°C (t - temperature of heat-transfer medium) |
Integrated data transmission system by radio | |
Operating frequency/data format | 868,95 MHz Wireless M-Bus |
Transmitter power | ~ 1 mW |
Transmission time | < 5 ms |
Data transmission scope (radius, range) | Up to 200 m (depending on local conditions) Note: You have to pay attention to all the metal structural components such as: concrete reinforcement, Lifts, etc. because they can affect adversely the radio range (the may be reduce the emitted signal) |