smartARS P pro
- Thermoplastics of V0 flammability class
- Fast installation using PPN technology
- Double clearance between open contacts
- Installation on to 185 mm busbar system
Parameter | smartARS 00 P pro | smartARS 2 P pro | smartARS 3 P pro | |||||
---|---|---|---|---|---|---|---|---|
Rated thermal current Ith with knife-blade fuses | A | 160 | 250 (NH1), 400 (NH2) | 630 | ||||
Rated thermal current Ith with knife links | A | 160 | 600 | 750 | ||||
Rated insulation voltage Un | V | 690 | 690 | 690 | ||||
Utilisation category | - | AC-22B | AC-23B | AC-22B | AC-23B |
AC-23B |
AC-22B | AC-21B |
Rated switching voltage Ue | V | 690 | 400 | 690 | 400 | 400 | 500 | 690 |
Rated switching current Ie | A | 160 | 250 (NH1), 400 (NH2) | 630 | ||||
Rated short circuit making current | kA | 80 dla 690 V | 100 dla 690 V | 80 dla 690 V | ||||
kA | 100 dla 500 V | 120 dla 500 V | 120 dla 500 V | |||||
Rated short circuit withstand current | kA | 80 dla 690 V | 100 dla 690 V | 100 dla 690 V | ||||
kA | 100 dla 500 V | 120 dla 500 V | 100 dla 500 V | |||||
Rated insulation voltage Ui | V | 1000 | 1000 | 1000 | ||||
Rated impulse withstand voltage Uimp | kV | 12 | 12 | 12 | ||||
Rated frequency | Hz | 50-60 | 50-60 | 50-60 | ||||
Mechanical durability | Number of cycles | 1000 | 1000 | 1000 | ||||
Electrical durability | 200 | 200 | 200 | |||||
IP degree of protection | - | 30 | 30 | 30 | ||||
Size of fuse links | - | 00 | 1; 2 | 3 |
Disconnectors smartARS 2 P pro – 400 A;
Installation on to 185 mm busbar system;
ONE-POLE SWITCHING - each phase independently
- smartARS 2-1-V P pro Cable terminal; V-terminals; V-clamp 240 mm2
- smartARS 2-1-M P pro Cable terminals: pressed nuts M12
- smartARS 2-1-2V P pro Cable terminal; 2V-terminals; double V-clamps 240 mm2
for installation on 185 mm busbar system,
THREE POLE SWITCHING - all phases simultaneously
- smartARS 2-6-V P pro Cable terminal; V-terminals; V-clamp 240 mm2
- smartARS 2-6-M P pro Cable terminals: pressed nuts M12
- smartARS 2-6-2V P pro Cable terminal; 2V-terminals; double V-clamps 240 mm2
Disconnectors smartARS 3 P pro – 630 A;
Installation on to 185 mm busbar system;
ONE-POLE SWITCHING - each phase independently
- smartARS 3-1-V P pro Cable terminal; V-terminals; V-clamp 240 mm2
- smartARS 3-1-M P pro Cable terminals: pressed nuts M12
- smartARS 3-1-2V P pro Cable terminal; 2V-terminals; double V-clamps 240 mm2
for installation on 185 mm busbar system,
THREE POLE SWITCHING - all phases simultaneously
- smartARS 3-6-V P pro Cable terminal; V-terminals; V-clamp 240 mm2
- smartARS 3-6-M P pro Cable terminals: pressed nuts M12
- smartARS 3-6-2V P pro Cable terminal; 2V-terminals; double V-clamps 240 mm2
Transformers used for current metering in smartARS P pro disconnectors 400 A and 630 A are incorporated in the base of the device and do not increase its size, it makes it possible to save space in a switchgear a cabinet. Technical parameters of the applied transformers:
- in smartARS 2 P pro – 400/5/0.5s 2.5VA
- in smartARS 3 P pro – 600/5/0.5s 2.5VA
Disconnectors have contact terminals enabling connecting signal cables from transformers.