RBK pro-X, RBK pro-XT
RBK pro-X, RBK pro-XT
Horizontal fuse switch disconnector with fuse monitoring module
- Thermoplastic parts of RBK pro fuse switch disconnectors
are made of fibre glass strengthened polyamide with halogen - Have highest possible flammability class – V0
- Arc chambers with steel deionization plates over top contacts
- Silver plated contacts providing low power loss
Parameters
Versions
Monitoring module
Downloads
- Operating voltage AC - 400÷ 690 V, 40÷ 60 Hz;
- Relay parameters 5A , 250 V~
CAUTION!
For use only with fuse-links with non-isolated gripping lugs!
Versions with electronic fuse monitoring module
- RBK 00 pro-XT For installation on mounting plate, power supply connected to top cable terminals
- RBK 00 pro-X For installation on mounting plate, power supply connected to top bottom terminals
- RBK 00 pro-SG-X For installation on to 60 mm busbar system, top cable terminals, busbar power supply
- RBK 00 pro-SD-XT For installation on to 60 mm busbar system, bottom cable terminals, busbar power supply
- RBK 1 pro-XT For installation on mounting plate, power supply connected to top cable terminals
- RBK 1 pro-X For installation on mounting plate, power supply connected to top bottom terminals
- RBK 1 pro-SG 60-X For installation on to 60 mm busbar system, top cable terminals, busbar power supply
- RBK 1 pro-SD 60-XT For installation on to 60 mm busbar system, bottom cable terminals, busbar power supply
- RBK 1 pro-SG 100-X For installation on to 100 mm busbar system, top cable terminals, busbar power supply
- RBK 1 pro-SD 100-XT For installation on to 100 mm busbar system, bottom cable terminals, busbar power supply
- RBK 2 pro-XT For installation on mounting plate, power supply connected to top cable terminals
- RBK 2 pro-X For installation on mounting plate, power supply connected to top bottom terminals
- RBK 2 pro-SG 60-X For installation on to 60 mm busbar system, top cable terminals, busbar power supply
- RBK 2 pro-SD 60-XT For installation on to 60 mm busbar system, bottom cable terminals, busbar power supply
- RBK 2 pro-SG 100-X For installation on to 100 mm busbar system, top cable terminals, busbar power supply
- RBK 2 pro-SD 100-XT For installation on to 100 mm busbar system, bottom cable terminals, busbar power supply
Electronic fuse monitoring module
- L1, L2, L3 diodes are flashing - all three phases are supplied, all fuse links are operational. Relay contacts: [21..22] - closed; [13..14] - opened
- L1, L2, L3 diodes are blinking - all three phases are supplied, fuse links operated Relay contacts: [21..22] - opened; [13..14] - closed
- L1, L2, L3 diodes are off - two or more phases are not supplied or fuse links are removed. Relay contacts: [21..22] - opened; [13..14] - closed