MH (DN55 i DN65); MWN50-GH; JSH (DN40)
MH (DN55 i DN65); MWN50-GH; JSH (DN40)
Hydrant water meters
- Mobility of measurements
- Easy reading of the water meter counter
- Hermetic counter
- Counter mechanism with blockade against multiple rotating, at rotation angle more than 360°
- Double-sided rotor bearing
Application
Measurement range
Features
Technical data
Downloads
MH – for immediate measuring of water volume with a temperature up to 30 °C through fast connection to underground hydrant with a diameter of 80 mm, on the maximum working pressure up to 10 bar (PN10). Hydrant outlet with quick-release connection, adapter size 75.
JSH-16 and MWN50-GH – for immediate measuring of water volume with a temperature up to 30 °C (JSH-16) and up to 50 °C (MWN50-GH) through fast connection to over ground hydrant DN80 and DN100 and with quick release connection, adapter size 75, on the maximum working pressure up to 16 bar (PN16). Water meter suitable for connection to hydrants with counters directed upwards.
- MH, JSH-16 - cold water R63
- JSH-16 - cold water R100
- MWN50-GH - cold water R100
- Possibility of immediate water capacity measurment by quick connection to underground hydrant 80 mm
- Counter of roller-pointer type housed in airtight casing with all gear wheels in dry space
- Magnetic clutch
- Conformity with the standards ISO 4064, BS 5728
Type* | R | Q3 [m3/h] | DN [mm] | Length [mm] | Connection |
---|---|---|---|---|---|
MH | R63 | 15 | 50 | 130* | connector 75T and adapter 52T |
MH | R63 | 25 | 65 | 130* | connector 75T and adapter 52T |
JSH-16 | R100 | 16 | 40 | 300 | connector 75T and adapter 52T |
MWN50-GH | R100 | 40 | 50 | 300 | connector 75T and adapter 52T |
MWN50-GH-NKOP | R100 | 40 | 50 | 300 | connector 75T and adapter 52T |
*) Size measured from the vertical inlet axis to external surface of outlet flange
Catalogue
Manual
Certificates